Details
⚙️ General Description
The ESR‑DA Series is FOTEK’s line of high-power DC‑to‑AC SSRs. The ESR‑40DA model is the standard version (no integrated heatsink/fan) designed for three-phase or single loads controlled by a DC signal.
🔌 Input & Output Specifications
-
Control Input (DC): 4–32 VDC
-
Turn‑off Threshold: < 3 VDC
-
Input Current: Max 30 mA
-
Control Method: Zero-cross switching (minimizes electrical noise)
-
Load Voltage (AC): 24–380 VAC
-
Max Continuous Current: 40 A
-
Surge Withstand:
-
Surge Current: ~410 A
-
I²t (fuse rating): ~664 A²·s
-
-
Leakage Current: ~5 mA when OFF
-
Response Time: ~8.3 ms (for 60 Hz systems)
🛡️ Protection & Durability
-
Overheat Protection: Built-in thermal cutoff at ≈120 °C; auto‐resets below ≈110 °C
-
Dielectric Strength: ≥ 4 kVrms
-
Insulation Resistance: ≥ 100 MΩ at 500 VDC
-
EMC Immunity: 2 kV surge protection per EN61000‑4‑4
-
Safety Approvals: Conforms to EN60947‑4‑3 and EN60950
📐 Environmental & Mechanical Details
-
Operating Temp & Humidity: –40 °C to +80 °C; 35–85 % RH
-
Construction: Robust module designed for industrial setups; mounting options vary by accessory selections.
✅ Use Cases
Ideal for:
-
Switching mid-power three-phase/single-phase AC loads (heaters, motors, etc.)
-
Applications requiring silent, spark-free operations and EM interference reduction
-
Industrial automation systems controlled by PLCs or microcontrollers
Thermal protection and high dielectric rating make it reliable in heavy‑duty environments.
🔄 Upgrades & Alternatives
-
For applications demanding higher output voltage ranges (up to 480 VAC), consider the ESR‑40DA‑H model.
-
If you need integrated cooling and overload protection, the ESR‑40DA+ version includes fuse, heatsink, and fan.
View more about FOTEK ESR-40DA on main site