FOTEK ESR-40DA

FOTEK ESR-40DA

Category: SSR

Specifications
Details

⚙️ General Description

The ESR‑DA Series is FOTEK’s line of high-power DC‑to‑AC SSRs. The ESR‑40DA model is the standard version (no integrated heatsink/fan) designed for three-phase or single loads controlled by a DC signal. 


🔌 Input & Output Specifications

  • Control Input (DC): 4–32 VDC

  • Turn‑off Threshold: < 3 VDC

  • Input Current: Max 30 mA

  • Control Method: Zero-cross switching (minimizes electrical noise) 

  • Load Voltage (AC): 24–380 VAC

  • Max Continuous Current: 40 A

  • Surge Withstand:

    • Surge Current: ~410 A

    • I²t (fuse rating): ~664 A²·s

  • Leakage Current: ~5 mA when OFF

  • Response Time: ~8.3 ms (for 60 Hz systems) 


🛡️ Protection & Durability

  • Overheat Protection: Built-in thermal cutoff at ≈120 °C; auto‐resets below ≈110 °C 

  • Dielectric Strength: ≥ 4 kVrms

  • Insulation Resistance: ≥ 100 MΩ at 500 VDC 

  • EMC Immunity: 2 kV surge protection per EN61000‑4‑4 

  • Safety Approvals: Conforms to EN60947‑4‑3 and EN60950 


📐 Environmental & Mechanical Details

  • Operating Temp & Humidity: –40 °C to +80 °C; 35–85 % RH 

  • Construction: Robust module designed for industrial setups; mounting options vary by accessory selections.


✅ Use Cases

Ideal for:

  • Switching mid-power three-phase/single-phase AC loads (heaters, motors, etc.)

  • Applications requiring silent, spark-free operations and EM interference reduction

  • Industrial automation systems controlled by PLCs or microcontrollers

Thermal protection and high dielectric rating make it reliable in heavy‑duty environments.


🔄 Upgrades & Alternatives

  • For applications demanding higher output voltage ranges (up to 480 VAC), consider the ESR‑40DA‑H model.

  • If you need integrated cooling and overload protection, the ESR‑40DA+ version includes fuse, heatsink, and fan.


View more about FOTEK ESR-40DA on main site