E+E ROOM SENSOR EE800-M11HV1A6 (CO2 + T), OUTPUT:4-20mA

E+E ROOM SENSOR EE800-M11HV1A6 (CO2 + T), OUTPUT:4-20mA

Category: SENSOR

Specifications
Details

The E+E Elektronik EE800-M11HV1A6 is a high-precision room sensor designed to simultaneously measure carbon dioxide (CO₂), temperature (T), and relative humidity (RH). This model features a 4–20 mA analog output, making it suitable for integration with industrial control systems and building automation setups.


📊 Key Specifications

  • CO₂ Measurement:

    • Range: 0 to 2000 ppm / 0 to 5000 ppm

    • Accuracy at 25°C (77°F):

      • ±(50 ppm + 2% of reading) for 0–2000 ppm

      • ±(50 ppm + 3% of reading) for 0–5000 ppm

    • Response Time (τ63): Approximately 110 seconds

    • Temperature Dependency: ±(1 + CO₂ concentration [ppm] / 1000) ppm/°C

    • Calibration Interval:

      5 years
  • Temperature Measurement:

    • Range: -20°C to +60°C (-4°F to +140°F)

    • Accuracy at 20°C (68°F):

      • ±0.3°C (±0.54°F) for voltage output

      • ±0.7°C (±1.26°F) for current output

  • Relative Humidity (RH):

    • Range: 10% to 90% RH

    • Accuracy at 20°C (68°F):

      • ±3% RH (30–70% RH)

      • ±5% RH (10–90% RH)

  • Dew Point Temperature:

    • Range: -30°C to +55°C (-22°F to +131°F)

    • Accuracy:

      • < ±2°C (3.6°F) for |T| - |Td| < 25°C (45°F)

      • < ±3°C (5.4°F) for |T| - |Td| < 30°C (54°F)

  • Outputs:

    • Analog: 4–20 mA (load resistance < 500 Ω)

    • Digital Interface: RS485 with Modbus RTU or BACnet MS/TP (optional)\

  • Supply Voltage:

    • 24 V AC ±20% or 15–35 V DC\

  • Current Consumption:

    • Analog Output: Typical 14 mA + output current; peak 0.3 A for 0.3 s

    • Digital Interface: Typical 11 mA at 15–35 V DC; peak 150 mA at 15–35 V DC\

  • Enclosure:

    • Material: Polycarbonate

    • Protection Class: IP30

    • Dimensions: 85 x 100 x 26 mm


🛠️ Applications

The EE800-M11HV1A6 is ideal for:

  • Demand-Controlled Ventilation (DCV): Optimizing indoor air quality and energy efficiency by adjusting ventilation based on CO₂ levels.

  • HVAC Systems: Monitoring and controlling temperature and humidity for comfort and equipment protection.

  • Building Automation: Integrating environmental data into smart building systems for enhanced management.

  • Indoor Air Quality Monitoring: Ensuring healthy and comfortable environments in offices, schools, and public spaces.


View more about E+E ROOM SENSOR EE800-M11HV1A6 (CO2 + T), OUTPUT:4-20mA on main site